Airlab Jumper Settings
Airlab from D&R Phone +31 294 418014, email: [email protected] Page 41
12.2 TRIPLE DIG INPUT MODULE
Figure 10: Airlab Triple Dig Module Jumper Locations
Options Jumpers Settings Settings Default
AUX PRE/POST J8 and J9 1 + 2 = POST 3 + 4 = PRE POST
LC MIC only J7 1+2 / 3+4 = ON No Jumper = OFF OFF
48 volt Phantom J13 1 + 2 = OFF 3 + 4 = ON OFF
Dig-Output J11 en J6 1+1 / 2+2 = SUB 3+3 / 4+4 = PROG Prog
FCLK Select J12 1 + 2 = Fixed 3 + 4 = PLL Fixed
Table 2: Airlab Triple Dig Module Jumper settings
Figure 11: Triple Dig Module AUX Jumper settings
Figure 12: Triple Dig Module MIC LC Jumper settings